AVEC-CHEM NBC-3/SL gas mask filter

49.90

NGOs & OFFICIAL AGENCIES: PLEASE CONTACT US BEFORE PURCHASE

NBC-3 / SL Product Sheet

AVEC-CHEM NBC-3/SL filter cartridge for use with gas masks or powered respirators, ensures the filtration of toxic agents to the respiratory tract - in particular all known CBRN toxic agents (vapors, gases, aerosols, contaminated dusts).

54 in stock (can be ordered)

WITH CHEM logo brand aresmaxima.com
SKU: WITH_NBC_CAN_-3SL Categories: , Tags: , ,

Description

AVEC-CHEM NBC-3/SL filter cartridge for use with gas masks or powered respirators, ensures the filtration of toxic agents to the respiratory tract - in particular all known CBRN toxic agents (vapors, gases, aerosols, contaminated dusts).

Canister class A2B2E2K2HgSXP3 D R & CE standardized EN 14387: 2004 - A1: 2008, manufactured from reinforced polymer,provides excellent thermal and mechanical resistance. (40 × 1/7 “ - 40mm thread compatible with all military and civilian NATO protection equipment or equipment of European or American manufacture.

Provides filtering against solid and liquid particles, pepper spray (OC), radioactive particles, bacteria and rickettsiae, fungi, toxins, viruses and riot control agents, vesicants, choking agents, blood agents, nerve agents, incapacitants, herbicides, pesticides and TICs, nuclear & organic substances, organic arsenic compounds, toxic industrial chemicals (including organic iodine compounds), and radioactive particles.

STORAGE PERIOD: 20 YEARS - IN ITS THERMO-SEALED COVER

Product data & resistance to inspiration / expiration (in pascal):

Technical DataBreathing Resistance in Pa Breathing Resistance in Pa
Diameter110 mm@ flow rate 30l / min. IN 1) WITH-CHEM NBC-3 / SL 260 <140@ flow rate 95l / min. IN 1) WITH-CHEM NBC-3 / SL 980 <600
Height85 mm
Weight335 g ± 5%
Storage time20 years (factory sealed)
  • 40mm NATO thread - standardization STANAG 4155 (IN 148-1)

Service life & filtration (in %):

  • Penetration resistance tested according to standard 14387 + A1 (70% humidity rate - 30L / m flow)
  • Resistance to radioactive iodine penetration (and its organic components): according to standard DIN 58621
  • Calculation of the effective service life in a contaminated area: concentration / DAC (Dynamic Adsorption Capacity) - CONTACT US FOR MATHEMATICAL FORMULATION
Type and Class Particle filter efficiency @ flow rate 95l / mParticle filter efficiency @ flow rate 95l / m
A2 - organic gases and vaporsSX - CG, CK, PSSodium Chloride NaCl (S) Paraffin Oil (L)99,95 99,95WITH-CHEM NBC-3 / SL> 99,999> 99,999
B2 - inorganic gases and vaporsP3 - particles
E2 - acid gases and vaporsD- dust
K2 - ammonia and aminesR- reusable
Hg - mercury vapors

Effective filtration:

Solid and liquid particles, pepper spray (OC), smoke-producing substances, radioactive particles, bacteria and rickettsiae, fungi, toxins, viruses, and riot control agents (e.g., fire retardants, sternutators). These include: vesicants, blistering agents, suffocating agents, blood agents, nerve agents, incapacitating agents, herbicides, pesticides and TICs, such as bromoacetone, CS, CR, CN, nuclear substances, organic substances, organic arsenic compounds - diphenyldichlorarsine - CLARK I (DA), diphenylcyanoarsine - CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA) ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulfur mustard gas (HD), mustard gas T, mustard gas Q, nitrogen mustard gas (HN1, HN2, HN3), lewisite (L), mixed mustard gas (HL), phosgene oxime (CX), phosgene (CG), diphosgene (DP), chloropicrin (PS), hydrocyanic acid (AC), cyanogen chloride (CK), arsine (SA), agents G Sarin (GB), Cyclo Sarin (GF), Soman (GD), Tabun (GA), IVA (GV), V agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: organic or inorganic acid vapors, hydroxides, organic solvents with boiling points above 65 ° C, ammonia, amines, inorganic and acidic gases, combustion gases from agricultural chemicals, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulfur oxides, chloroacetic acid, aldehydes, mixtures of inorganic acids and organic substances, mercury vapors, radioactive iodine, organic iodine compounds (Iodomethane, 129), radioactive particles.

Testing GasConcentration of Testing GasBreakthrough Time in Minutes ENWITH-CHEM NBC-3 / SLDAC in Grams WITH-CHEM NBC-3 / SL
ppmmg / l
A2cyclohexaneC₆H₁₂500017.5353920,475
B2ChlorineCl₂500015204520,250
Sulphide HydrogenH₂S50007.140> 80> 17,400
Cyanide HydrogenHCN50005.625508,400
E2Sulfur DioxideSO₂500013.320259,975
K2AmmoniaNH₃50003.540505,250
HgMercuryHg—–13 mg / m³Two hours> 170 hours> 3900
SXCyanogen chlorideICCON25006.2820254,710
chloropicrinCCI₃NO₃500033.55204444,286
PhosgeneCOCl₃500020.2420> 77> 47,058

DEPENDING ON THE TOXIC AGENT, THE CARTRIDGE MUST BE CHANGED IMMEDIATELY ONCE THE SATURATION POINT IS REACHED

Storage:

  • In a cool room, without light, regularly ventilated, without any electrical or chemical material
  • Maximum relative humidity of 95%
  • Temperature range between -30° and +50°C (SEALED CARTRIDGE)

After use:

  • Once the cartridge is full:
    • Comply with recovery instructions from civil or military authorities
  • IF YOU ARE IN SURVIVAL PHASE:
    • Store the filters in an airtight bag & bury them in an identified area (to be considered as polluted and unusable)
    • If you can, seal the cartridges in concrete, lead ...

Brand

Avec Chem

WITH CHEM logo brand aresmaxima.com