Gas Mask Filter AVEC-CHEM NBC-1/SL, for use on gas masks or powered respirators, ensures filtration of agents toxic to the respiratory tract – including all known CBRN toxic agents (vapors, gases, aerosols, contaminated dusts).

Out of stock

Description

Gas Mask Filter AVEC-CHEM NBC-1/SL, for use on gas masks or powered respirators, ensures filtration of agents toxic to the respiratory tract – including all known CBRN toxic agents (vapors, gases, aerosols, contaminated dusts).

Cartridge classified A2B1E1K1P3 DR & CE standardized EN 14387: 2004 - A1: 2008, manufactured from reinforced polymer,provides excellent thermal and mechanical resistance. (40 × 1/7 “ - 40mm thread compatible with all military and civilian NATO protection equipment or equipment of European or American manufacture.

Provides filtering against solid and liquid particles, pepper spray (OC), radioactive particles, bacteria and rickettsiae, fungi, toxins, viruses and riot control agents, vesicants, choking agents, blood agents, nerve agents, incapacitants, herbicides, pesticides and TICs, nuclear & organic substances, organic arsenic compounds, toxic industrial chemicals (including organic iodine compounds).

STORAGE PERIOD: 20 YEARS - IN ITS THERMO-SEALED COVER

Product data & resistance to inspiration / expiration (in pascal):

Technical Data Breathing Resistance in Pa Breathing Resistance in Pa
Diameter 110 mm @ flow rate 30l / min. IN 1) WITH-CHEM OF-07 260 <140 @ flow rate 95l / min. IN 1) WITH-CHEM OF-07 980 <600
Height 85 mm
Weight 335 g ± 5%
Storage time 20 years (factory sealed)
  • Gas Mask Filter AVEC-CHEM NBC-1/SL
  • 40mm NATO thread - standardization STANAG 4155 (IN 148-1)
  • NSN: 4240-16-007-1400

Service life & filtration (in %):

  • Penetration resistance tested according to standard 14387 + A1 (70% humidity rate - 30L / m flow)
  • Resistance to the penetration of radioactive iodines (and its organic components): according to standard DIN 58621
  • Calculation of the effective service life in a contaminated area: concentration / DAC (Dynamic Adsorption Capacity) - CONTACT US FOR MATHEMATICAL FORMULATION
Type and Class Particle filter efficiency @ flow rate 95l / m Particle filter efficiency @ flow rate 95l / m
A2 - organic gases and vapors Sodium Chloride NaCl (S) Paraffin Oil (L) 99,95 99,95 NBC-77 SOF> 99,999> 99,999
B1 - inorganic gases and vapors P3 - particles
E1 - acid gases and vapors D- dust
K1 - ammonia and amines R- reusable

Effective filtration:

The AVEC-CHEM NBC-1/SL filter cartridge combined with a suitable respirator offers protection against solid and liquid particles, pepper spray (OC), smoke substances, radioactive particles, bacteria and rickettsia, fungi toxins, viruses, Riot Control (Lachrymators, Sternutators, Vomiting), Vesicants, Choking agents, Blood agents, Incapacitants, Herbicides, Pesticides and TICs, such as Bromoacetone, CS, CR, CN, CNS, CA substances, organic arsenic compounds - diphenyl dichlorarsine - CLARK I (DA), diphenylcyanoarsine - CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulfur mustard gas (HD), mustard gas T Sarin (GB), cyclosarin (GF), soman (GD), tabun (GA), IVA (GV), agents V: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: organic or inorganic acid fumes, hydroxides, organic solvents with boiling point above 1 °C, ammonia, amines, inorganic and acidic gases, combustion gases from agricultural chemicals, other toxic substances, e.g. Other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulfur oxides, chloroacetic acid, aldehydes, mixtures of inorganic acids and organic substances.

Testing Gas Concentration of Testing Gas Breakthrough Time in Minutes EN OF-07 DAC in Grams WITH-CHEM OF-07
ppm mg / l
A2 cyclohexane C₆H₁₂ 5000 17.5 35 37 19.425
B1 Chlorine Cl₂ 1000 3.00 20 > 30 > 2.700
Sulphide Hydrogen H₂S 1000 1.4 40 > 60 > 2.520
Cyanide Hydrogen HCN 1000 1.1 25 > 160 > 5.820
E1 Sulfur Dioxide SO₂ 1000 2.7 20 > 30 > 2.430
K1 Ammonia NH₃ 1000 0.7 50 > 60 > 1.260

 

DEPENDING ON THE TOXIC AGENT, THE FILTER MUST BE CHANGED IMMEDIATELY ONCE THE SATURATION POINT IS REACHED

Storage:

  • In a cool room, without light, regularly ventilated, without any electrical or chemical material
  • Maximum relative humidity of 95%
  • Temperature range between -30° and +50°C (SEALED CARTRIDGE)

After use:

  • Once the cartridge is full:
    • Comply with recovery instructions from civil or military authorities
  • IF YOU ARE IN SURVIVAL MODE:
    • Store the filters in an airtight bag & bury them in an identified area (to be considered as polluted and unusable)
    • If you can, seal the cartridges in concrete, lead ...