Gas mask with chem CM-6 v1 from aresmaxima.comGas mask with chem CM-6 v7 from aresmaxima.comGas mask with chem CM-6 v2 from aresmaxima.comGas mask with chem CM-6 v3 from aresmaxima.comGas mask with chem CM-6 v4 from aresmaxima.comGas mask with chem CM-6 v5 from aresmaxima.comGas mask with chem CM-6 v6 from aresmaxima.com

AVEC-CHEM CM-6 Tactical Gas mask for CBRN Defense

194.90

🛡️ EUROPEAN UNION LOGISTICS

• Shipped from European warehouses
• 14-day statutory right of return applicable
• Your order will be processed manually within 5 hours

Made in the Czech Republic – shipped from the Czech Republic

Gas mask AVEC-CHEM CM-6 – designed to provide optimum viewing area and comfort, provides protection of the respiratory tract and face against CBRN toxic agents (vapors, gases, aerosols, contaminated dusts) in conjunction with either filter cartridges or a powered respirator.

57 in stock

SKU: WITH_NBC_MASK_CM6 Categories: , , , Tags: , ,

Description

Tactical Gas Mask WITH-CHEM CM-6: Full Protection Against CBRN/NRC

Le AVEC-CHEM CM-6 Tactical Gas mask for CBRN Defense It is designed to ensure maximum field of vision and optimal comfort in degraded or non-permissive situations. It guarantees absolute protection of the respiratory tract and face against CBRN toxic agents (vapors, gases, aerosols, contaminated dust) in conjunction with either standardized filter cartridges or a powered air-purifying respirator.

Standard mask CE EN 136: 1998, Class III & EN 148-1 (Threaded). Its construction from bromobutyl rubber (vulcanized polyisobutylene) ensures maximum impermeability to TICs (Toxic Industrial Chemicals) and CWAs (Chemical Warfare Agents), as well as excellent thermal and mechanical resistance. The hypoallergenic silicone inner half-mask guarantees a perfect seal without any fogging, even during sustained exertion, while significantly reducing CO2 buildup in the mask and offering low mechanical resistance during inhalation/exhalation (greatly reducing physiological stress on the wearer).

🛡️ Security Architecture: The Crucial Importance of the RD40 Filter

⚠️ NOTE TO USERS / SURVIVALISTS: A gas mask alone is a sealed shell that filters nothing without its cartridge. To effectively equip your CM-6 against real threats, you absolutely must pair it with active filters. Discover our range of 40mm NATO CBRN filters available here to complete your waterproof protection.

Two side threads (40×1/7" – 40mm NATO standard) allow the addition of two filter cartridges simultaneously – depending on the saturation of the atmosphere with the toxic agent – ​​or a single cartridge (the second thread being locked and sealed to allow the shouldering of a long gun). The hydration system – compatible with CAMELBACK type A & M adapters – is immediately operational.

The integrated communication system allows for 95% speech intelligibility up to a distance of 2 to 3 meters, without sound distortion. The mask is secured by a head harness (rubber and fabric) designed for wearing a ballistic helmet, with the possibility of integrating prescription glasses (not supplied) into the compartment provided in the mask if needed.

LIFETIME: 20 YEARS / MANUFACTURER WARRANTY: 05 YEARS
WATERPROOFING TESTED BY EXPOSURE TO "MUSTARD" GAS FOR 30 HOURS

📊 Overall Product Data

  • Model: AVEC-CHEM CM-6 Tactical Gas mask for CBRN Defense
  • Facepiece material: Bromobutyl rubber (vulcanized polyisobutylene) – one size fits all
  • Panoramic view: 180° visor (made of high-strength polycarbonate polymer)
  • Comfort: Hypoallergenic silicone inner half-mask – permanent anti-fog system
  • Tactical compatibility: Designed for wearing with a ballistic helmet and integrating eyeglasses
  • Hydration: Integrated hydration system compatible with CAMELBACK adapters
  • Phonics: High-performance sound system – 95% clear speech understanding
  • Harness: Attachment via ergonomic head harness (05 adjustable straps)
  • Connection : Two 40mm NATO threads for the simultaneous use of two 40mm cartridges or for SCBA/breathing apparatus connection

🚫 Usage Prohibitions and Legal Limitations

  • Prohibited in an atmosphere with an oxygen level below 19,5% – below this, a self-contained breathing apparatus (SCBA) is mandatory.
  • Prohibited in an explosive atmosphere above class 01 (for Europe and France refer to the ATEX classification – zone 01).
  • To ensure optimal sealing and to validate overpressure tests, wearing a beard or long hair is strongly discouraged.

🌍 Military Standardization & Validations

  • Mask and mask sub-assembly: 136: 1998, class III
  • Filter mounting threads: EN 148-1
  • In operational service with the armed forces: Saudi Arabia, Czech Republic, Norway, Portugal, Chile, Turkey, Kuwait, Latvia & Lebanon.

📐 Advanced Technical Data

  • Weight: 560g
  • Speech intelligibility: 95 %
  • General field of vision: min. 70% | Binocular field of vision: min. 80%
  • Filter connection: Rd 40 x 1/7″ (International Standard)
  • Mechanical resistance to inspiration (flow 30l/min): max. 30 Pa (Pascal)
  • Mechanical resistance during expiration (flow rate 30l/min): max. 60 Pa (Pascal)

📦 Storage Recommendations

  • Store in a cool, dark, regularly ventilated area, away from any electrical equipment or volatile chemicals nearby.
  • Maximum relative humidity of 65%.
  • Optimal storage temperatures are within a range of 10° to 25°C.