AVEC-CHEM OF-07M gas mask filter

49.90

🛡️ EUROPEAN UNION LOGISTICS

• Shipped from European warehouses
• 14-day statutory right of return applicable
• Your order will be processed manually within 5 hours

NGOs & OFFICIAL AGENCIES: PLEASE CONTACT US BEFORE PURCHASE

OF-07M product sheet

Gas Mask Filter AVEC-CHEM OF-07M for use on gas mask or powered respirator, ensures filtration of agents toxic to the respiratory tract – including all known CBRN toxic agents (vapors, gases, aerosols, contaminated dusts) and radioactive particles.

134 in stock

Description

Gas Mask Filter AVEC-CHEM OF-07M, NATO standard, for use on gas mask or powered respirator, ensures filtration of agents toxic to the respiratory tract – including all known CBRN toxic agents (vapors, gases, aerosols, contaminated dusts) and radioactive particles.

Gas Filter class A2B2E1SXP3 DR REACTOR & CE standardized EN 14387: 2004 - A1: 2008, manufactured from reinforced polymer,provides excellent thermal and mechanical resistance. (40 × 1/7 “ - 40mm thread compatible with all military and civilian NATO protection equipment or equipment of European or American manufacture.

Provides filtering against solid & liquid particles, pepper spray (OC), radioactive particles, bacteria & rickettsiae, fungi, toxins, viruses & riot control agents, blistering, suffocating, blood, neurotoxic, incapacitating agents, herbicides, pesticides and TICs, nuclear & organic substances, organic arsenic compounds, toxic industrial chemicals (including organic iodine compounds), and radioactive particles - Radioactive Iodine (131, 132 ), including radioactive methane iodide.

STORAGE PERIOD: 20 YEARS - IN ITS THERMO-SEALED COVER

COMBAT GAS FILTRATION

HUMIDITY INDICATOR WITH COLOR CODE

Product data & resistance to inspiration / expiration (in pascal):

Technical Data Breathing Resistance in Pa Breathing Resistance in Pa
Diameter 110 mm @ flow rate 30l / min. IN 1) WITH-CHEM OF-07 260 <140 @ flow rate 95l / min. IN 1) WITH-CHEM OF-07 980 <600
Height 85 mm
Weight 335 g ± 5%
Storage time 20 years (factory sealed)
  • Gas Mask Filter AVEC-CHEM OF-07M
  • 40mm NATO thread - standardization STANAG 4155 (IN 148-1)
  • NSN: 4240-16-007-3490

Service life & filtration (in %):

  • Penetration resistance tested according to standard 14387 + A1 (70% humidity rate - 30L / m flow)
  • Resistance to the penetration of radioactive iodines (and its organic components): according to standard DIN 58621
  • Calculation of the effective service life in a contaminated area: concentration / DAC (Dynamic Adsorption Capacity) - CONTACT US FOR MATHEMATICAL FORMULATION
Type and Class Particle filter efficiency @ flow rate 95l / m Particle filter efficiency @ flow rate 95l / m
A2 - organic gases and vapors SX - CG, CK, PS Sodium Chloride NaCl (S) Paraffin Oil (L) 99,95 99,95 NBC-77 SOF> 99,999> 99,999
B2 - inorganic gases and vapors P3 - particles
E1 - acid gases and vapors D- dust
R- reusable
REACTOR

Effective filtration:

Solid and liquid particles, pepper spray (OC), smoke-emitting substances, radioactive particles, bacteria and rickettsiae, fungi, toxins, viruses and riot control agents (pressure reducers, sternutators). , blistering agents), blistering agents, suffocating agents, blood agents, nerve agents, incapacitating agents, herbicides, pesticides and TICs, such as bromoacetone, CS, CR, CN, nuclear substances, organic substances, organic arsenic compounds – diphenyldichlorarsine – CLARK I (DA), diphenylcyanoarsine – CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulfur mustard gas (H), sulfuric gas (HD), Mustard gas T, mustard gas Q, nitrogen mustard gas (HN1, HN2, HN3), lewisite (L), mixed mustard gas (HL), phosgene oxime (CX), phosgene (CG), diphosgene (DP), chloropicrin (PS), hydrogen cyanide (AC), cyanogen chloride (CK), arsine (SA), G agents: sarin (GB), cyclo sarin (GF), soman (GD), tabun (GA), IVA (GV), V agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: vapours of organic or inorganic acids, hydroxides, organic solvents with a boiling point above 65 ° C, ammonia, amines, inorganic and acid gases, flue gases of agricultural chemicals, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, chloroacetic acid, aldehydes, mixtures of inorganic acids and organic substances, mercury vapours, radioactive iodine, organic iodine compounds (Iodomethane, 129, 131), radioactive particles.

Testing Gas Concentration of Testing Gas Breakthrough Time in Minutes EN OF-07 DAC in Grams WITH-CHEM OF-07
ppm mg / l
A2 cyclohexane C₆H₁₂ 5000 17.5 35 39 20,475
B2 Chlorine Cl₂ 5000 15 20 45 20,250
Sulphide Hydrogen H₂S 5000 7.1 40 > 80 > 17,400
Cyanide Hydrogen HCN 5000 5.6 25 50 8,400
E1 Sulfur Dioxide SO₂ 1000 13.3 20 25 9,975
NBC Cyanogen chloride (CK) CICN 2500 06.28 20 > 30 > 5,652
Chloropicrin (PS) CCl3NO2

Phosgene (CG)COCl3

Sarin (GB) C4H10FO2P

Mustard gas (HD) C4H8CL2S

Soman C7H16FO2P

DMMP C3H903P

5000

5000

174

60

135

5000

33.55

20.24

01.00

00.40

01.00

25.37

20

20

67

167

67

35

 

> 30

> 25

> 300

> 750

> 300

> 35

 

> 30,195

> 15,180

> 9,000

> 9,000

> 9,000

> 26,642

SX Cyanogen chloride ICCON 2500 6.28 20 25 4,710
chloropicrin CCI₃NO₃ 5000 33.55 20 44 44,286
Phosgene COCl₃ 5000 20.24 20 > 77 > 47,058
TCM Ammonia NH3 500 00.35 > 20 > 0.210

 

DEPENDING ON THE TOXIC AGENT, THE FILTER MUST BE CHANGED IMMEDIATELY AT THE SATURATION POINT REACHED

Storage:

  • In a cool room, without light, regularly ventilated, without any electrical or chemical material
  • Maximum relative humidity of 95%
  • Temperature range between -30° and +50°C (SEALED CARTRIDGE)

After use:

  • Once the cartridge is full:
    • Comply with recovery instructions from civil or military authorities
  • IF YOU ARE IN SURVIVAL MODE:
    • Store the filters in an airtight bag & bury them in an identified area (to be considered as polluted and unusable)