Gas Mask Filter AVEC-CHEM NBC-3/SL for use on gas masks or powered respirators, ensures filtration of toxic agents to the respiratory tract – including all known CBRN toxic agents (vapors, gases, aerosols, contaminated dusts).
Gas Filter class A2B2E2K2HgSXP3 D R & CE standardized EN 14387: 2004 - A1: 2008, manufactured from reinforced polymer,provides excellent thermal and mechanical resistance. (40 × 1/7 “ - 40mm thread compatible with all military and civilian NATO protection equipment or equipment of European or American manufacture.
Provides filtering against solid and liquid particles, pepper spray (OC), radioactive particles, bacteria and rickettsiae, fungi, toxins, viruses and riot control agents, vesicants, choking agents, blood agents, nerve agents, incapacitants, herbicides, pesticides and TICs, nuclear & organic substances, organic arsenic compounds, toxic industrial chemicals (including organic iodine compounds), and radioactive particles.
STORAGE PERIOD: 20 YEARS - IN ITS THERMO-SEALED COVER
Product data & resistance to inspiration / expiration (in pascal):
| Technical Data | Breathing Resistance in Pa Breathing Resistance in Pa | ||
|---|---|---|---|
| Diameter | 110 mm | @ flow rate 30l / min. IN 1) WITH-CHEM NBC-3 / SL 260 <140 | @ flow rate 95l / min. IN 1) WITH-CHEM NBC-3 / SL 980 <600 |
| Height | 85 mm | ||
| Weight | 335 g ± 5% | ||
| Storage time | 20 years (factory sealed) | ||
- Gas Mask Filter AVEC-CHEM NBC-3/SL
- 40mm NATO thread - standardization STANAG 4155 (IN 148-1)
Service life & filtration (in %):
- Penetration resistance tested according to standard 14387 + A1 (70% humidity rate - 30L / m flow)
- Resistance to radioactive iodine penetration (and its organic components): according to standard DIN 58621
- Calculation of the effective service life in a contaminated area: concentration / DAC (Dynamic Adsorption Capacity) - CONTACT US FOR MATHEMATICAL FORMULATION
| Type and Class Particle filter efficiency @ flow rate 95l / m | Particle filter efficiency @ flow rate 95l / m | |||
|---|---|---|---|---|
| A2 - organic gases and vapors | SX - CG, CK, PS | Sodium Chloride NaCl (S) Paraffin Oil (L) | 99,95 99,95 | WITH-CHEM NBC-3 / SL> 99,999> 99,999 |
| B2 - inorganic gases and vapors | P3 - particles | |||
| E2 - acid gases and vapors | D- dust | |||
| K2 - ammonia and amines | R- reusable | |||
| Hg - mercury vapors | ||||
Effective filtration:
Particules solides et liquides, le gaz poivré (OC), les substances dégageant de la fumée, les particules radioactives, les bactéries et les rickettsies, les champignons, les toxines, les virus et les agents de lutte antiémeute (détendeurs, sternutateurs). , agents vésicants), agents vésicants, agents suffoquants, agents sanguins, agents neurotoxiques, agents incapacitants, herbicides, pesticides et TIC, tels que bromoacétone, CS, CR, CN, substances nucléaires, substances organiques, composés organiques de l’arsenic – diphenyldichlorarsine – CLARK I (DA), diphénylcyanoarsine – CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), éthyldichlorarsine (ED), méthyldichlorarsine (MD), gaz moutarde (H), gaz moutarde sulfureux (H), gaz sulfurique (HD), Gaz moutarde T, gaz moutarde Q, gaz moutarde à l’azote (HN1, HN2, HN3), lewisite (L), gaz moutarde mélangé (HL), phosgène oxime (CX), phosgène (CG), diphosgène (DP), chloropicrine (PS), acide cyanhydrique (AC), chlorure de cyanogène (CK), Arsine (SA), agents G: sarin (GB), cyclo sarin (GF), soman (GD), tabun (GA), IVA (GV), agents V: VX, VR, VE, VG (amiton), VM et produits chimiques industriels toxiques tels que: vapeurs d’acides organiques ou inorganiques, hydroxydes, solvants organiques dont le point d’ébullition est supérieur à 65 ° C, ammoniac, amines, gaz inorganiques et acides, gaz de combustion de produits chimiques agricoles, autres substances toxiques, par exemple benzène, toluène, chlorure de vinyle, fluor, fluorure d’hydrogène, oxydes de soufre, acide chloroacétique, aldéhydes, mélanges d’acides inorganiques et substances organiques, vapeurs de mercure, iode radioactive, composés organiques de l’iode (Iodométhane, 129, 131), particules radioactives.
| Testing Gas | Concentration of Testing Gas | Breakthrough Time in Minutes EN | WITH-CHEM NBC-3 / SL | DAC in Grams WITH-CHEM NBC-3 / SL | |||
|---|---|---|---|---|---|---|---|
| ppm | mg / l | ||||||
| A2 | cyclohexane | C₆H₁₂ | 5000 | 17.5 | 35 | 39 | 20,475 |
| B2 | Chlorine | Cl₂ | 5000 | 15 | 20 | 45 | 20,250 |
| Sulphide Hydrogen | H₂S | 5000 | 7.1 | 40 | > 80 | > 17,400 | |
| Cyanide Hydrogen | HCN | 5000 | 5.6 | 25 | 50 | 8,400 | |
| E2 | Sulfur Dioxide | SO₂ | 5000 | 13.3 | 20 | 25 | 9,975 |
| K2 | Ammonia | NH₃ | 5000 | 3.5 | 40 | 50 | 5,250 |
| Hg | Mercury | Hg | —– | 13 mg / m³ | 100 hours | > 170 hours | > 3900 |
| SX | Cyanogen chloride | ICCON | 2500 | 6.28 | 20 | 25 | 4,710 |
| chloropicrin | CCI₃NO₃ | 5000 | 33.55 | 20 | 44 | 44,286 | |
| Phosgene | COCl₃ | 5000 | 20.24 | 20 | > 77 | > 47,058 | |
DEPENDING ON THE TOXIC AGENT, THE FILTER MUST BE CHANGED IMMEDIATELY ONCE THE SATURATION POINT IS REACHED
Storage:
- In a cool room, without light, regularly ventilated, without any electrical or chemical material
- Maximum relative humidity of 95%
- Temperature range between -30° and +50°C (SEALED CARTRIDGE)
After use:
- Once the gas mask filter AVEC-CHEM NBC-3/SL saturated:
- Comply with recovery instructions from civil or military authorities
- IF YOU ARE IN SURVIVAL MODE:
- Store the filters in an airtight bag & bury them in an identified area (to be considered as polluted and unusable)
- If you can, seal the cartridges in concrete, lead ...