Developped by AVEC CHEM, the broad spectrum suit “AVEC-MS-2” protects the skin and mucous membranes from toxic and infectious agents – including all known CBRN toxic agents (vapors, gases, aerosols, contaminated dust) – supplied with its OM-90 gas mask (including 1 filtration cartridge), gloves & overshoes
CBRN suit AVEC-MS-2 & its OM-90 mask – a set developed by AVEC CHEM, the broad spectrum suit “AVEC-MS-2” protects the skin and mucous membranes from toxic and infectious agents – including all known CBRN toxic agents (vapors, gases, aerosols, contaminated dust) – supplied with its OM-90 gas mask (including 1 filtration cartridge), gloves & overshoes – all components of the set are NATO & ISO 6940: 2004 (flame retardant).
Perfectly suited to CBRN defense, combat and rescue operations - depending on the logistical and decontamination capacity of your organization - this set can be stored, washed, decontaminated and worn over a long period of time, without compromising the level of protection - within the limits indicated.
CBRN suit AVEC-MS-2 & its OM-90 mask – complete set with suit, mask, filter, overshoes & gloves
The CBRN suit AVEC-MS-2 & its OM-90 mask:
COMPOSITION:
Jacket with double closure - locking at the waist - with hood & glove attachment
Pants - waist lock and overshoes attachment
TECHNICAL DATA :
Activated carbon filtration - carbon spheres
Complies with NATO CBRN standards
Minimum 30 days of wearing time
Minimum 10 washes at 40 ° C without reducing the protective performance
Minimum shelf life of 10 years if the combination is stored in its original packaging under appropriate storage conditions
Flame retardant according to ISO 6940:2004 – retains its retardant properties after 05 washes
DESIGN FEATURES:
Fully ergonomic and very light (2,3 kg - 2,5 kg)
Front zipper covered with a special flap for easy on and more protection
Integrated hood fits most models of CBRN gas masks on the market
Double-layered closure at the end of the sleeve and foot
Elastic loop at the end of each cuff - Adjustable size for a better fit
Available in sizes XS to 4XL
EXTERNAL COATING:
MaterialComposition 65% cotton + 35% polyester
Weight 175 ± 15g / m2
Mechanical properties resistance to chain breaking (ISO 13934-1): min 950 N (ISO 13934-1)Weft: min 500 N
Mechanical properties tear resistance Warp (ISO 13937-1): min 22 N Weft: min 18 N
Water resistance (spray test) (EN 244920): Original min 5 After 5x wash ISO 6330, 4N (40 ° C), F (tumbler), iron min 4
Hydrocarbon test AATCC 118-2013 - Hydrocarbon test: Original min 6 After 5x wash ISO 6330, 4N (40 ° C), F (tumbler), iron min 4
Air permeability (ISO 9237) Min 250 mm / s (air flow at 100Pa)
Fire resistance ISO 6940: 2004: validated
Color Any type of camouflage, olive green, sand, black, navy blue, white
INTERNAL COATING:
Material: INSIDE layer with strongly adherent hard spherical activated carbon grains: in quantity of 200 ± 15 g / m2
Diameter of the spheres: 0,4 mm - 0,7 mm
Homogeneous distribution of carbon spheres: Evenly distributed - maximum distance between 2 spheres is not more than 1 mm
Product data & resistance to inspiration / expiration (in pascal):
Technical Data
Breathing Resistance in Pa Breathing Resistance in Pa
Diameter
110 mm
@ flow rate 30l / min. EN 1) NBC-77 SOF 260 <140
@ flow rate 95l / min. EN 1) NBC-77 SOF 980 <600
Height
85 mm
Weight
335 g ± 5%
Storage time
20 years (factory sealed)
40mm NATO thread - standardization STANAG 4155 (IN 148-1)
Service life & filtration (in %):
Penetration resistance tested according to standard 14387 + A1 (70% humidity rate - 30L / m flow)
Resistance to the penetration of radioactive iodines (and its organic components): according to standard DIN 58621
Calculation of the effective lifetime in a contaminated area: concentration / DAC (Dynamic Adsorption Capacity - CONTACT US FOR MATHEMATICAL FORMULATION
Type and Class Particle filter efficiency @ flow rate 95l / m
Particle filter efficiency @ flow rate 95l / m
A2 - organic gases and vapors
SX - CG, CK, PS
Sodium Chloride NaCl (S) Paraffin Oil (L)
99,95 99,95
NBC-77 SOF> 99,999> 99,999
B2 - inorganic gases and vapors
P3 - particles
E2 - acid gases and vapors
D- dust
K2 - ammonia and amines
R- reusable
Hg - mercury vapors
REACTOR - radioactive iodine
Effective filtration:
Solid and liquid particles, pepper spray (OC), smoke-emitting substances, radioactive particles, bacteria and rickettsiae, fungi, toxins, viruses and riot control agents (pressure reducers, sternutators). , blistering agents), blistering agents, suffocating agents, blood agents, nerve agents, incapacitating agents, herbicides, pesticides and TICs, such as bromoacetone, CS, CR, CN, nuclear substances, organic substances, organic arsenic compounds – diphenyldichlorarsine – CLARK I (DA), diphenylcyanoarsine – CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulfur mustard gas (H), sulfuric gas (HD), Mustard gas T, mustard gas Q, nitrogen mustard gas (HN1, HN2, HN3), lewisite (L), mixed mustard gas (HL), phosgene oxime (CX), phosgene (CG), diphosgene (DP), chloropicrin (PS), hydrogen cyanide (AC), cyanogen chloride (CK), arsine (SA), G agents: sarin (GB), cyclo sarin (GF), soman (GD), tabun (GA), IVA (GV), V agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: vapours of organic or inorganic acids, hydroxides, organic solvents with a boiling point above 65 ° C, ammonia, amines, inorganic and acid gases, flue gases of agricultural chemicals, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, chloroacetic acid, aldehydes, mixtures of inorganic acids and organic substances, mercury vapours, radioactive iodine, organic iodine compounds (Iodomethane, 129, 131), radioactive particles.
Testing Gas
Concentration of Testing Gas
Breakthrough Time in Minutes EN
NBC-77 SOF
DAC in Grams NBC-77 SOF
ppm
mg / l
A2
cyclohexane
C₆H₁₂
5000
17.5
35
39
20,475
B2
Chlorine
Cl₂
5000
15
20
45
20,250
Sulphide Hydrogen
H₂S
5000
7.1
40
> 80
> 17,400
Cyanide Hydrogen
HCN
5000
5.6
25
50
8,400
E2
Sulfur Dioxide
SO₂
5000
13.3
20
25
9,975
K2
Ammonia
NH₃
5000
3.5
40
50
5,250
Hg
Mercury
Hg
—–
13 mg / m³
100 hours
> 170 hours
> 3900
SX
Cyanogen chloride
ICCON
2500
6.28
20
25
4,710
chloropicrin
CCI₃NO₃
5000
33.55
20
44
44,286
Phosgene
COCl₃
5000
20.24
20
> 77
> 47,058
REACTOR
Methyloidide₁₃₁
CH₃I
-
-
2 hours
> 2 hours
-
DEPENDING ON THE TOXIC AGENT, THE FILTER MUST BE CHANGED IMMEDIATELY AT THE SATURATION POINT REACHED
NRBC gloves & undergloves:
Separate glove designs for left and right hands
Produced according to NATO AEP-38 standard
High resistance to hazardous chemicalsProtection capacity:> 24 hours
Butyl rubber material
Available in 3 sizes: SML
Ease of use with cotton inner gloves - PROVIDED
Enhanced mobility design with finger and wrist gusset